Array Spectrometer MCPD-9800
Multipurpose spectrometer covering UV to NIR wavelength range. Shortest integration time is 5ms. Using optical fiber, various measurement optics can be configured for versatile application, including micro spot spectrum, light source, transmittance, reflectance, object color and thickness measurement.
Are you interested in alliance or distributorship for this product? |
|
- Product
- MCPD-9800
- MCPD-6800
- Applications
Product
There are three models with twelve wavelength ranges, including flag ship model of MCPD-9800. No matter what customer needs and application, we propose best suitable model to you.。
General purpose USB port and LAN port equipped for user’s convenient and wider application.
Monitoring UV/VIS/NIR spectrum with either 512ch or 1024ch detector at 5msec interval is possible with high speed and high precision.
Using standard optical fiber, flexible optics can be configured without any restriction of sample shape and sizes. Besides, microscope and large sample stage can also be integrated, achieving superior performance in any industrial fields
MCPD series satisfies every required accuracies for spectrophotometer based on.
Japan Industrial Standard, JIS Z 8724
|
Otsuka Electronics is accredited as optical calibration service provider compliant with JCSS(Japan Calibration Service System)
- Also accredited as international MRA (Mutual Recognition Arrangement) compliance calibration service provider.
- Provides optical traceability which is required for measurement of lighting products
And accredited as test provider for optical performance evaluation for LED and general lighting products based upon JNLA (Japan National Laboratory Accreditation System)
- Also accredited as international MRA compliance JNLA test provider.
- Provides evaluation data compliant with JIS(Japan Industry Standard) of optical property measurement , in order to fairly evaluate lighting products
Otsuka Electronics contributes to recognition and growth of eco-environment friendly lighting appliances by providing optical measurement traceability and its technologies.
Otsuka Electronics provides customer cutting edge and turnkey solution using long expertise and wide knowledge, as well as various optical accessories,optional unit and analysis software.
MCPD-9800
Array Spectrometer MCPD-9800
- Wide dynamic range suitable for luminous flux measurement
- Stray light correction function equipped for UV measurement. Now only 20% of stray light level compared to last generation model
- Wide integration time range between 5msec and 65sec, suitable for very weak light source, high speed needs and production line
- Equipped scrambling fiber to achieve high reproducibility.
- Light weight and compact. 60% downsizing from last generation model.
- Luminescence Spectrum
- Transmission/Absorption Spectrum
- Reflection Spectrum
- Photoluminescence
- Object Color
- Light Source Color (Chromaticity, Luminance, Illuminance)
- Film Thickness
- Plasma Emission Spectrum
Model | MCPD-9800 | ||||||||
2285C | 3095C | 3683C | 311C | 916C | |||||
Wavelength Range(nm) | 220~850 | 300~950 | 360~830 | 360~1100 | 900~1600 | ||||
Spectroscope | Flat Field Type | ||||||||
Detector (ch) |
Electro-cooling CCD Image Sensor |
Electro-cooling
|
|||||||
512 | 1024 | 512 | 1024 | 512 | 1024 | 512 | 1024 | 512 | |
Theoretical Resolution (nm) |
1.4 | 0.7 | 1.4 | 0.7 | 1.0 | 0.5 | 1.6 | 0.8 | 1.9 |
Optical Fiber | Quartz Scramble Fiber,φ12 mm, 2 meter long | Ge-doped Quartz Fiber, 2 meter long |
|||||||
Integration time | 5ms~20s | 1ms~10s | |||||||
Interface | USB or LAN | ||||||||
Power and voltage | 125VA, Single phase AC100-240V 50/60Hz | ||||||||
Size and weight | 105(W)×230(H)×280(D)mm, 6kg |
MCPD-6800
Array Spectrometer MCPD-6800
MCPD-6800 is entry grade spectrometer for spectrum measurement and analysis. Using optical fiber and various accessories, flexible measurement optics can be configured for versatile user application. Wavelength range can be chosen from four types.
- Luminescence Spectrum
- Transmission/Absorption Spectrum
- Reflection Spectrum
- Photoluminescence
- Object Color
- Light Source Color (Chromaticity, Luminance, Illuminance)
- Film Thickness
- Plasma Emission Spectrum
Model | MCPD-6800 | |||
2285C | 3095C | 3683C | 3610C | |
Wavelength Range(nm) | 220~850 | 300~950 | 360~830 | 360~1000 |
Spectroscope | Flat Field Type | |||
Detector (ch) |
Electro-cooling PDA | |||
512 | 512 | 512 | 512 | |
Theoretical Resolution (nm) |
1.5 | 1.5 | 1.1 | 1.7 |
Optical Fiber | Quartz Fiber φ12 mm, 2 meter long | |||
Integration time | 16ms~65s | |||
Interface | USB or LAN | |||
Power and voltage | 100VA, Single phase AC100-230V 50/60Hz | |||
Size and weight | 105(W)×215(H)×280(D)mm, 5.5kg |
Applications
Luminescence |
Applications ◎Luminescence and Photoluminescence ◎PDP fluorescence measurement |
Luminous flux |
Applications ◎Luminous flux of LED and EL |
Goniophotometer |
Applications ◎Spectrum distribution by angle using motorized goniophotometer ◎Angle dependent distribution of light intensity and color |
Surface color measurement |
Applications |
Reflectance |
Applications ◎Surface characteristics of optical material and reflector ◎Glasses ◎Anti reflection film |
Transmission / Absorbance |
Applications ◎Color control and test of painted surface ◎Paper and printed materials ◎Textile, powder and plastic |
Thickness |
Applications ◎Thickness of film and coating on various substrate such as wafer, glass and aluminum |
Microscopic measurement |
Applications ◎Micro spot measurement under microscope (Reflectance, Transmittance, Absorbance) ◎Thickness of various film and coating |
Solution measurement |
Applications |
Multi point measurement |
Applications ◎Reflectance spectrum of anti reflection film ◎Coating film ◎Films on various substrate |
Production line |
Applications ◎Thickness and reflectance of anti reflection film ◎Quality control of function film |
- Product
- MCPD-9800
- MCPD-6800
- Applications